LVdc Conduit Clamps

Method of determination
Calculated
Estimated accuracy
100%
string
String Inverter architecture
String Inverter with AC Combiner architecture
string+
Central Inverter architecture
central

These clamps are used for conduits at various points. For conduits that transition to the DC trench which are routed to the string inverter, for conduits crossing the PV tracker central motor gap, and for conduits at the end of the PV table attached to the torque tube. The calculation for each of these is the same.

Calculation

\[ \begin{align*} n_{trench} &=2 \times n_{tables} n_{motor\_gap} &=2 \times n_{tables} n_{torque\_tube} &=2 \times n_{tables} \end{align*} \]

where:

\[ \begin{align} n_{trench} &= \text{Number of clamps for conduits transitioning to the DC trench} \\ n_{motor\_gap} &=\text{Number of clamps for conduits crossing the motor gap} \\ n_{torque\_tube} &=\text{Number of clamps for conduits attached to the torque tube} \\ n_{tables} &= Number of PV tables \end{align} \]

‼️ This value is auto generated by AUTOPV™, subsequent modification may invalidate the design outcomes.